Current Location: Home>News>Company news

Adjustment method of electronic belt scale

Time:7/6/2023  From:EACCOR

With the rapid development of modern industry, the application of electronic belt scales is becoming increasingly widespread. Whether in the packaging industry or other industries, it is a common weighing device. High measurement accuracy can bring great convenience to users, but if used improperly, it can cause significant errors. Below is the calibration of electronic belt scales.
 
 
1. Weighing rack
 
The weighing frame of the electronic belt scale should be selected as long and stable as possible, and the force should be transferred to the weighing frame. During installation, it should be leveled as much as possible, and the electronic belt scale should be cleaned frequently to avoid dust affecting the effectiveness of the electronic belt scale.
 
2. Drum
 
The drum of the electronic belt scale can choose flexible rotation methods and small jumping rollers to ensure that each group of rollers is as uniform as possible.
 
3. Load Cell
 
The weighing sensor is used to weigh the weight of materials on the electronic belt scale; When selecting a weighing sensor, it is necessary to select a linear weighing sensor and increase the pre pressure to make the sensor work in the linear area.